Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Rev. colomb. anestesiol ; 51(4)dic. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535702

RESUMO

Introduction Anesthetists play an important role during interventional radiology procedures. Like the main operator, anesthetists may also be subject to significant radiation levels in the fluoroscopy suite. Due to its complexity, hepatic chemoembolization procedures demand high fluoroscopic times and digital subtraction angiography images, exposing patients and medical staff to high radiation doses. Objective To assess and quantify the radiation to which one anesthetist was exposed over the course of seven consecutive hepatic chemoembolization procedures, and compare it to the exposure received by the main operator. Methods Medical staff dosimetry was evaluated during seven consecutive hepatic chemoembolization procedures conducted in a private hospital in Recife (Brazil), using thermoluminiscent dosimeters placed in regions of the head and torso. Results For the seven procedures evaluated in this study, the anesthetist received, on average, absorbed doses to the glabella, left eyebrow, right eyebrow and effective dose of 142.4 ± 72 µSv, 117.3 ± 66 µSv, 137.8 ± 71 µSv and 12.4 ± 8.4 µSv, respectively. Conclusions In some cases, ocular dose and effective dose received by the anesthetist may be 4 and 4.7 times greater, respectively, when compared to the main operator. According to the results of this study, the current occupational annual dose limit to the lens of the eye of 20 mSv can be exceeded with only two hepatic chemoembolization procedures per week if adequate radiation protection conditions are not guaranteed.


Introducción El anestesiólogo desempeña un papel importante durante los procedimientos de radiología intervencionista. Al igual que el operador principal, el anestesiólogo también puede estar expuesto a niveles significativos de radiación en la sala de fluoroscopía. Debido a su complejidad, durante los procedimientos de quimioembolización hepática se deben utilizar imágenes de fluoroscopía y angiografía de sustracción digital por períodos prolongados, exponiendo a los pacientes y al personal médico a dosis elevadas de radiación. Objetivo Evaluar y cuantificar la radiación a la cual se expuso un anestesiólogo durante el transcurso de siete procedimientos consecutivos de quimioembolización hepática, y comparar con la exposición recibida por el operador principal. Métodos Evaluación de la dosimetría ocupacional durante siete procedimientos consecutivos de quimioembolización hepática realizados en un hospital privado de Recife (Brasil) por medio de dosímetros termoluminiscentes ubicados en regiones de la cabeza y el torso. Resultados Para los siete procedimientos evaluados en este estudio, el anestesiólogo recibió, en promedio, dosis absorbidas en el entrecejo, la ceja izquierda, la ceja derecha y dosis efectivas de 142,4 ± 72 µSv, 117,3 ± 66 µSv, 137,8 ± 71 µSv y 12,4 ± 8,4 µSv, respectivamente. Conclusiones En algunos casos, la dosis ocular y la dosis efectiva que recibe el anestesiólogo puede ser, respectivamente, entre 4 y 4,7 veces más alta que la que recibe el operador principal. De acuerdo con los resultados de este estudio, el límite ocupacional anual de dosis en cristalino (20 mSv) se puede superar con apenas dos procedimientos de quimioembolización hepática a la semana en caso de no garantizarse las condiciones adecuadas de protección contra la radiación.

2.
J. health med. sci. (Print) ; 7(4): 215-221, oct.-dic. 2021.
Artigo em Espanhol | LILACS | ID: biblio-1396092

RESUMO

El objetivo del presente artículo ha sido describir el programa "Optimización de la Protección en Radiología Intervencionista Pediátrica en América Latina y el Caribe" (OPRIPALC) que nace el año 2018 como respuesta conjunta de la Organización Panamericana de la Salud y la Organización Mundial de la Salud, en cooperación con el Organismo Internacional de Energía Atómica, para colaborar con sus Estados miembros en asegurar que las exposiciones a la radiación de los pacientes pediátricos sean las mínimas necesarias durante los procedimientos intervencionistas. Actualmente, hay 18 centros de los siguientes 10 países que participan: Argentina, Brasil, Chile, Colombia, Costa Rica, Cuba, Ecuador, México, Perú y Uruguay. Para el desarrollo del programa se plantean una serie de objetivos, productos, actividades y resultados esperados. La puesta en marcha de la WEB de OPRIPALC ha significado un instrumento muy válido para seguir la información actualizada del programa. Un programa actualizado de formación en radioprotección para los profesionales implicados en el programa, se está realizando por medio de "webinars". Se deberá seguir actuando en la aplicación del programa de control de calidad básico para los equipos de rayos X participantes y validar los valores de los Niveles de Referencia para Diagnóstico (NRDs). Se propone formar un equipo de trabajo entre los Físicos Médicos y Tecnólogos Médicos participantes de OPRIPALC para implicarse en las pruebas de control básicas que todos los centros debieran realizar. Se han presentado algunos resultados iniciales de OPRIPALC en eventos científicos internacionales. Se está avanzando en proponer unos primeros valores sobre NRDs en procedimientos de intervencionismo cardiológico pediátrico por bandas de edad y peso. OPRIPALC es una de las pocas iniciativas de carácter regional para obtener valores de NRDs en procedimientos intervencionistas pediátricos. Se espera que tanto los valores de referencia como la metodología empleada en OPRIPALC, puedan ser utilizados en otras regiones del mundo.


The objective of this article has been to describe the program "Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean" (OPRIPALC) that was born in 2018 as a joint response of the Pan American Health Organization and the World Organization of the Health, in cooperation with the International Atomic Energy Agency, to collaborate with its member states in ensuring that radiation exposures of pediatric patients are the minimum necessary during interventional procedures. Currently, there are 18 centers from the following 10 countries participating: Argentina, Brazil, Chile, Colombia, Costa Rica, Cuba, Ecuador, Mexico, Peru and Uruguay. For the development of the program, a series of objectives, products, activities and expected results are proposed. The launch of the OPRIPALC WEBSITE has been a very valid instrument for following up-to-date information on the program. An updated training program in radiation protection for the professionals involved in the program is being carried out through webinars. It should continue acting in the application of the basic quality control program for the participating X-ray equipment and validate the values of the Diagnostic Reference Levels (DRLs). It is proposed to form a work team among the OPRIPALC participating medical physicists to get involved in the basic control tests that all centers should carry out. Some initial results of OPRIPALC have been presented at international scientific events. Progress is being made in proposing first values on DRLs in pediatric cardiac intervention procedures by age and weight bands. OPRIPALC is one of the few regional initiatives to obtain DRLs values in pediatric interventional procedures. It is expected that both the reference values and the methodology used in OPRIPALC can be used in other regions of the world.


Assuntos
Humanos , Criança , Pediatria/normas , Proteção Radiológica/normas , Cardiologia/normas , Controle de Qualidade , Padrões de Referência , Valores de Referência , Segurança , Radiologia Intervencionista , Região do Caribe , Técnicas de Diagnóstico Cardiovascular , Otimização de Processos , Níveis de Referência de Diagnóstico , América Latina
3.
CES odontol ; 34(1): 52-67, ene.-jun. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1360261

RESUMO

Resumen El uso de rayos X juega un papel esencial en el diagnóstico y planificación de tratamientos dentales. Los avances tecnológicos de los equipos de rayos X han contribuido al mayor uso de este tipo de radiación en la práctica odontológica. Aunque la exposición a la radiación es baja en estos procedimientos, todavía existe un riesgo que debe reducirse al mínimo necesario a fin de obtener una imagen adecuada para el diagnóstico y a la vez evitar efectos nocivos para el paciente y el personal involucrado. Debido al alto y creciente número de radiografías dentales, el hecho de que niños y adolescentes sean el foco de la mayoría de estas, la subestimación de la cantidad de exámenes radiológicos reportados y la supuesta baja conciencia de estudiantes y profesionales de la odontología sobre los peligros del uso indiscriminado de los rayos X, es necesario adoptar medidas de protección radiológica para mitigar los efectos biológicos radioinducidos. Este artículo tiene como objetivo revisar los principios básicos de la radioprotección que deben considerarse en la práctica dental, con el fin de garantizar el menor daño posible a trabajadores ocupacionalmente expuestos, pacientes y miembros del público.


Resumo O uso dos raios X desempenha um papel essencial no diagnóstico e planejamento de tratamentos dentários. O avanço tecnológico nos equipamentos de raios-X tem contribuído para o aumento do uso deste tipo de radiação na prática odontológica. Embora a exposição à radiação seja baixa nestes procedimentos, ela representa um risco e deve ser reduzida ao mínimo valor necessário para se obter a imagem adequada para o diagnóstico, evitando efeitos nocivos ao paciente e ao pessoal envolvido. Devido ao elevado e crescente número de radiografias odontológicas, ao fato de crianças e adolescentes serem o foco de grande parte delas, a subestimação do número de exames radiológicos notificados e a suposta baixa conscientização de estudantes e profissionais da odontologia sobre os perigos dos uso indiscriminado de raios-x, é precisa a adoção de medidas de radioproteção para mitigar o risco de efeitos nocivos radioinduzidos. Este artigo tem como objetivo revisar os princípios básicos da radioproteção a serem considerados na prática odontológica, a fim de garantir o menor prejuízo possível para trabalhadores ocupacionalmente expostos, pacientes e membros do público.


Abstract The use of X-rays plays an essential role in the diagnosis and planning of dental treatments. Technological advances in X-ray equipment have contributed to the increased use of this type of radiation in dental practice. Although radiation exposure is low in these procedures, there is still a risk. The reduction of the risk to the minimum value possible is necessary to obtain an adequate image for the diagnosis and avoiding harmful effects on the patient and the personnel involved. Due to the high and growing number of dental X-rays, the fact that children and adolescents are the focus of most of them, the underestimation of the number of radiological examinations reported and the supposed low awareness of dental students and professionals about the dangers the indiscriminate use of X-rays, it is necessary to adopt radioprotection measures to mitigate the risk of harmful radioinduced effects. This article aims to review the basic principles of radioprotection to be considered in dental radiology, in order to ensure the least possible damage to occupationally exposed workers, patients and public members.

4.
Res. Biomed. Eng. (Online) ; 33(2): 138-143, Apr.-June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-896174

RESUMO

Abstract Introduction Digital mammography present many advantages in comparison to conventional mammography, such as high dynamic range and the post-processing of acquired images. One problem is that protocols may not be optimized, resulting in higher absorbed doses to patients. The objective of this work is to evaluate image quality and to estimate mean glandular doses (MGD) in patients submitted to mammography examinations with three digital systems and one screen-film system in Recife, Brazil. Methods To estimate the MGD, the parameters used to acquire images of 5475 patients, with ages between 40 and 64 years and compressed breasts between 2 and 9 cm, were registered. The MGD was calculated by multiplying the incident air kerma with conversion coefficients depending on the anode/filter, breast glandularity and half-value layer. The image quality evaluation of the digital systems was made using objective and subjective European criteria. Results The results showed MGDs in the range of 0.4-10.3 mGy and the higher values were observed with digital systems. It was also observed that in the digital systems the use of compression force is not adequate and the irradiation parameters are not optimized. The images failed to reproduce the pectoral muscle and the contrast-to-noise ratio was not adequate for one system, indicating the need to improve the patient's positioning and the exposure parameters. Conclusion It can be concluded that the use of non-optimized irradiation parameters is causing the higher doses with digital systems, highlighting the insufficient compression force.

5.
Radiol. bras ; 49(2): 79-85, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-780923

RESUMO

Abstract Objective: To estimate the entrance surface air kerma (Ka,e) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. Materials and Methods: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the Ka,e using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. Results: The Ka,e values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. Conclusion: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses.


Resumo Objetivo: Estimar o kerma no ar na superfície de entrada (Ka,e) e o kerma no ar na região de órgãos radiossensíveis em radiografias pediátricas dos seios paranasais. Materiais e Métodos: Foram coletados os dados dos pacientes e parâmetros de irradiação em exames de seios paranasais de crianças com 0 a 15 anos, em dois hospitais infantis na cidade do Recife, PE. O Ka,e foi estimado utilizando os rendimentos dos tubos de raios X e os parâmetros selecionados. Os valores de kerma no ar nas regiões dos olhos e tireoide foram estimados utilizando dosímetros termoluminescentes. Resultados: Os valores de Ka,e variaram de 0,065 a 1,446 mGy para radiografias cavum, 0,104 a 7,298 mGy para Caldwell e 0,113 a 7,824 mGy para Waters. Os valores de kerma no ar na região dos olhos variaram de 0,001 a 0,968 mGy para cavum e 0,011 a 0,422 mGy para Caldwell e Waters. Na região tireóidea, os valores de kerma no ar variaram de 0,005 a 0,932 mGy para cavum e 0,002 a 0,972 mGy para Caldwell e Waters. Conclusão: Os parâmetros de irradiação utilizados pelas instituições foram mais elevados do que os recomendados em protocolos britânicos. Ações de otimização são recomendadas de modo a contribuir para a redução da radiação nos pacientes e, portanto, os riscos.

6.
In. Guimarães, Marcos Duarte; Chojniak, Rubens. Oncologia. Rio de Janeiro, Elservier, 2014. p.845-869, ilus, 22, ilusuras.
Monografia em Português | LILACS | ID: lil-751108
7.
Radiol. bras ; 46(6): 351-357, Nov-Dec/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-699252

RESUMO

Objective The present study was aimed at estimating the doses received by physicians and patients during cerebral angiography procedures in a public hospital of Recife, PE, Brazil. Materials and Methods The study sample included 158 adult patients, and during the procedures the following parameters were evaluated: exposure parameters (kV, mAs), number of acquired images, reference air kerma value (Ka,r) and air kerma-area product (PKA). Additionally, the physicians involved in the procedures were evaluated as for absorbed dose in the eyes, thyroid, chest, hands and feet. Results The results demonstrated that the doses to the patients' eyes region were relatively close to the threshold for cataract occurrence. As regards the physicians, the average effective dose was 2.6 µSv, and the highest effective dose recorded was 16 µSv. Conclusion Depending on the number of procedures, the doses received by the physicians may exceed the annual dose limit for the crystalline lenses (20 mSv) established by national and international standards. It is important to note that the high doses received by the physicians are due to the lack of radiation protection equipment and accessories, such as leaded curtains, screens and protective goggles. .

8.
Radiol. bras ; 45(2): 83-86, mar.-abr. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-624456

RESUMO

OBJETIVO: Estimar a dose extracraniana nos olhos, tireoide, tórax e pelve em pacientes submetidos a radiocirurgia com acelerador linear de 6 MV. MATERIAIS E MÉTODOS: Foram avaliados 11 pacientes com tumores cerebrais primários (7 pacientes) e secundários (4 pacientes), sendo que dois destes apresentavam duas lesões. Para a estimativa da dose extracraniana, foram utilizados dosímetros termoluminescentes. Foram utilizados cones de 1,50 a 3,75 cm e as doses de radiação variaram de 1300 a 2000 cGy. RESULTADOS: A idade média dos pacientes foi de 52 anos, sendo 63,6% do sexo feminino e 36,4% do sexo masculino. As localizações das lesões foram: nervo acústico direito (1), frontal (2), parietal (5), occipital direito (1), cerebelar (2) e parassagitais (2). Os valores médios das doses recebidas na região entre os olhos foram de 5,1 cGy; no olho direito, de 4,8 cGy; no olho esquerdo, de 6,5 cGy; na tireoide, de 4,2 cGy; no tórax, de 1,65 cGy; e na pelve, de 0,45 cGy. CONCLUSÃO: Estes resultados mostram que embora as doses não ultrapassem os limites de tolerância para ocorrência da opacidade do cristalino, é importante que os médicos radioterapeutas considerem os riscos de dose de radiação nessas regiões durante o planejamento de procedimentos de radiocirurgia craniana.


OBJECTIVE: To estimate extracranial doses on eyes, thyroid, chest and pelvis in patients submitted to radiosurgery with 6 MV linear accelerator. MATERIALS AND METHODS: The present study evaluated 11 patients, 7 of them with primary, and 4 with secondary brain tumors. In the latter group, 2 patients had two lesions. Thermoluminescent dosimeters were utilized to estimate the extracranial dose. Radiosurgery cones ranges between 1.50 and 3.75 cm and doses between 1300 and 2000 cGy. RESULTS: Mean patients' age was 52 years, and 63.6% of them were women and 36.4%, men. Lesion locations were the following: right acoustic nerve (1), frontal (2), parietal (5), right occipital (1), cerebellum (2) and parasagittal (2). Mean received doses were the following: 5.1 cGy between the eyes; 4.8 cGy in the right eye; 6.5 cGy in the left eye; 4.2 cGy in the thyroid; 1.65 cGy in the chest; and 0.45 cGy in the pelvis. CONCLUSION: The results demonstrate that that although the eye doses do not exceed the tolerance limits for occurrence of lens opacity, it is important that the risks associated with radiation doses are taken into consideration by radiotherapists in the planning of cranial radiosurgery procedures.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/radioterapia , Radiação Ionizante , Radiocirurgia , Radiometria/normas , Radioterapia/normas , Olho , Aceleradores de Partículas , Pelve , Tórax , Glândula Tireoide
9.
ROBRAC ; 20(52)abr. 2011. tab
Artigo em Português | LILACS | ID: lil-609189

RESUMO

Objetivos: Este estudo avaliou a qualidade de imagens radiográficas expostas em consultórios odontológicos e processadas nos próprios consultórios por cirurgiões-dentistas e/ou auxiliares ou em laboratório, por pesquisadores. Métodos: Dezoito consultórios odontológicos participaram da pesquisa. Cada um recebeu um par de caixas de filmes periapicais Kodak Ektaspeed, os quais foram expostos conjuntamente, com um molar inferior extraído. O tempo de exposição variou em função do consultório odontológico. A auxiliar e/ou o cirurgião-dentista realizaram o processamento de um dos filmes, com as mesmas técnicas e recursos utilizados habitualmente (Grupo 1). O outro filme foi processado por pesquisadores em no Laboratório de Metrologia da Universidade de Pernambuco (Grupo 2). Por meio de questionário, dois radiologistas avaliaram a nitidez, densidade, contraste, definição do esmalte, dentina e junção amelodentinária, erros presentes nas imagens e se cada imagem podia ser suficiente para um bom diagnóstico. A análise estatística foi analisada utilizando o teste do Qui-quadrado e o teste exato de Fisher. Resultados: O Grupo 2 demonstrou maior número de radiografias com baixa densidade e radiografias escuras (p<0,05). O Grupo 1 apresentou maior número de radiografias claras, com pontos escuros, pontos marrons e radiografias arranhadas (p<0,05). Não houve diferença estatística significante em relação à nitidez, contraste, definição do esmalte, dentina e junção amelodentinária, presença de pontos claros e capacidade de levar a um bom diagnóstico (p>0,05). Conclusões: Este estudo sugeriu que imagens radiográficas produzidas em consultórios odontológicos apresentam imperfeições na técnica de execução e no processamento. Entretanto, apesar da importância do correto processamento radiográfico, a sobre-exposição de filmes foi a maior causa de falhas na qualidade da imagem.


This work aims evaluate subjectively the quality of radiographic images exposed in dental offices and processed in proper dental offices by surgeon-dentists and/or assistants or in laboratory, by researchers. Methods: Eighteen dental offices integrated the research. Each one received a pair of Kodak Ektaspeed periapical films which was exposed together with an extracted inferior molar. The exposition time varied in function of each dental office. The assistant and/or surgeon dentist carried through the processing of one of the films, with the same technique and resources used habitually (Group 1). The other film was processed by researchers in the Laboratory of Metrology of Federal University of Pernambuco (Group 2). Through a questionnaire, two radiologists evaluated the sharpness, density, contrast, definition of enamel, dentine and amelodentinary junction, errors present in the images and if each image would be enough for a good diagnosis. Results: Through Chi-Square or Fisher´s Exact test, it was observed that Group 2 got a bigger number of radiographs with low density and dark radiographs (p-value<0,05). Group 1 presented a bigger number of clear radiographs, with dark spots, brown spots and scratch radiographs (p-value<0,05). There wasn?t statistical significant difference in relation to sharpness, contrast, definition of enamel, dentine, and amelodentinary junction, presence of clear spots and the capacity of carrying through a good diagnosis (p-value> 0.05). Conclusions: This study suggested that radiographic images produced in dental office present imperfections in technique execution and in the processing. However, despite the importance of a correct radiographic processing, the overexposure of the films was the major cause of flaws in image quality.

10.
Radiol. bras ; 44(2): 90-96, mar.-abr. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-588194

RESUMO

OBJETIVO: Este trabalho teve como objetivo estimar os valores de doses de radiação recebidas por médicos e pacientes em procedimentos intervencionistas cardíacos realizados em um hospital público na cidade de Recife, Pernambuco. MATERIAIS E MÉTODOS: As medidas foram determinadas em 31 pacientes adultos, dos quais 22 tiveram acompanhamento clínico após o procedimento, e em dois cardiologistas com mais de dez anos de experiência. Parâmetros de irradiação para cada procedimento foram registrados. RESULTADOS: Os valores obtidos para a dose absorvida máxima na pele do paciente variaram entre 612 e 8.642 mGy, sendo que 53 por cento foram maiores que 2.000 mGy, valores estes que podem causar efeitos determinísticos. Com relação aos médicos, a dose efetiva média por procedimento foi de 11 µSv e os valores médios do equivalente de dose nas extremidades, mais altos, foram: 923 µSv no pé esquerdo, 514 µSv no pé direito, 382 µSv na mão esquerda e 150 µSv no olho esquerdo. Dependendo do número de procedimentos, as doses recebidas pelos médicos podem exceder os valores limites de doses estabelecidos pelas normas nacionais e internacionais. CONCLUSÃO: Os resultados obtidos sinalizam a necessidade de adoção de estratégias para otimização da proteção radiológica tanto de pacientes quanto de médicos.


OBJECTIVE: The present study was aimed at estimating the values of radiation doses received by physicians and patients during interventional cardiology procedures performed at a public hospital in the city of Recife, Pernambuco, Brazil. MATERIALS AND METHODS: Measurements were made in two cardiologists with more than ten years of experience and in 31 adult patients, with 22 of them being clinically followed-up after the procedure. The individual irradiation parameters were documented. RESULTS: The values for maximum patients skin dose ranged between 612 and 8,642 mGy, achieving more than 2,000 mGy in 53 percent of the patients; such dose values may cause deterministic effects. As regards the physicians, the mean effective dose per procedure was 11 µSv, and the highest mean equivalent doses in the limbs were 923 µSv in the left foot, 514 µSv in the right foot, 382 µSv in the left hand, and 150 µSv in the left eye. Depending on the number of procedures, the doses received by the physician may exceed the dose limits established by the Brazilian and international standards. CONCLUSION: The obtained results indicate the necessity of adopting strategies for optimizing the radiological protection for both patients and physicians.

11.
Rev. bras. ciênc. saúde ; 13(3): 15-22, set.-dez. 2009.
Artigo em Português | LILACS | ID: lil-602517

RESUMO

Objetivo: Avaliar a radiopacidade dos cimentos endônticos Fillcanal, Apexit, Vidrion Endo e Endométhasone, variandose filmes radiográficos periapicais D-Speed, E-Speed e Agfa Dentus M2 Comfort e dois tempos de exposição. Material e Métodos: Foram confeccionados 5 corpos de prova para cada material estudado, os quais foram radiografados, juntamente com um dente, nos tempos de exposição e filmes estudados. Em cada imagem do corpo de prova e do dente, foram obtidas medidas da densidade óptica. Foram utilizados os testes de Kruskal-Wallis e de Mann-Whitney, com o nível de significância de 0,05. Resultados: Os valores da densidade óptica do dente e dos cimentos mostraram-se diferentes quando se variou filme e/ou tempo de exposição. Em todas as condições estudadas, o dente apresentou valores da densidade óptica maiores que os dos cimentos. O cimento Vidrion Endo mostrou-se mais radiopaco seguido, em ordem decrescente, pelo Fillcanal, Endométhasone e Apexit na maioria das condições estudadas. Com exceção do cimento Vidrion Endo, por não ter demonstrado alteração da radiopacidade variando-se o tipo de filme utilizando-se menor tempo de exposição, houve diferenças nos resultados quanto ao tipo de filme e tempo de exposição em todos os casos. Conclusão: Os fatores tempo de exposição e filme influenciam na radiopacidade dos materiais.


Objective: The radiopacity of the endodontic sealers Fillcanal, Apexit, Vidrion Endo and Endométhasone, was assessed, with three periapical radiographic films: D-Speed, E-Speed and Agfa Dentus M2 Comfort and two exposure times. Material and Methods: Five test specimens were made for each material studied, which were radiographed together with a teeth, at the exposure times and with the films studied. In each test specimen and tooth image, optic density measurements were obtained. The Kruskal-Wallis test and the Mann-Whitney test was used, with level of significance of 0.05. Results: The optic density values of the tooth and the cements were shown to differ with the film and/or exposure time that was varied. Under all the studied conditions, the tooth presented higher optical density values than those of the sealers. The Vidrion Endo sealer was shown to be the most radiopaque, followed by Fillcanal, Endométhasone and Apexit in decreasing order, under the majority of the studied conditions. With exception of the Vidrion Endo cement, since it showed no alteration in radiopacity when varying the type of radiographic film and using a shorter exposure time, there were differences in the results regardings the type of film and exposure time in all cases. Conclusion: The factors exposure time and film influence the radiopacity of the materials.


Assuntos
Cimentos Dentários , Filme para Raios X , Fenômenos Físicos , Radiografia Dentária
12.
Radiol. bras ; 41(5): 325-329, set.-out. 2008. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-496937

RESUMO

OBJETIVO: Os objetivos deste trabalho são: a) avaliar os procedimentos radiográficos e estimar o valor do kerma no ar na superfície de entrada nos recém-nascidos prematuros submetidos a exames de tórax e abdome, realizados no setor de neonatologia de um hospital público de Belo Horizonte; b) estimar as doses nos órgãos e os respectivos riscos de ocorrência de câncer nesses órgãos em decorrência das exposições à radiação. MATERIAIS E MÉTODOS: Foram analisados os prontuários dos pacientes internados no setor de neonatologia desse hospital durante o período de maio a setembro de 2004, anotando-se os dados antropométricos, data de internação/alta, exames de raios X realizados. O kerma no ar na superfície de entrada foi determinado a partir do rendimento do tubo de raios X e dos parâmetros de irradiação utilizados nos exames. As doses nos órgãos foram estimadas com o software PCXMC e o risco, durante o restante da expectativa de vida, com o software IREP. RESULTADOS: O valor médio do kerma no ar na superfície de entrada por exame foi abaixo do nível de referência da publicação da Comunidade Européia. Para o paciente mais severamente irradiado, os órgãos mais suscetíveis à ocorrência de câncer foram fígado, mama e estômago, com valores máximos de excess relative risk, respectivamente, de 3,4 por cento, 2,3 por cento e 1,7 por cento. CONCLUSÃO: Foi constatada a necessidade de otimização dos procedimentos radiográficos com vista à diminuição do risco para os recém-nascidos, que apesar de ser considerado baixo (comparativamente ao benefício), deve ser sempre diminuído para valores tão baixos quanto razoavelmente exeqüíveis.


OBJECTIVE: The present study was aimed at: a) evaluating radiographic procedures and estimating entrance surface air kerma in preterm neonates submitted to chest and abdominal radiography at the unit of neonatology in a public hospital of Belo Horizonte, MG, Brazil; b) estimating the dose to organs and respective risks for cancer as a result from radiation exposure. MATERIALS AND METHODS: Records of patients admitted to the unit of neonatology of this hospital in the period between May and September 2004 were reviewed. Anthropometric data, admission/discharge dates and radiographic studies performed were recorded for each of the patients. The calculation of the entrance surface air kerma was based on the x-ray tube output and irradiation parameters adopted for examinations. Dose to organs was calculated with the aid of the software PCXMC, and the lifetime risk for cancer, with the software IREP. RESULTS: Mean entrance surface air kerma per examination was below the diagnostic reference levels recommended by the European Community. In the most severely irradiated patients, liver, breast and stomach were the organs at highest risk for cancer, with maximum excess relative risk of respectively 3.4 percent, 2.3 percent, and 1.7 percent. CONCLUSION: The present study demonstrated the need for optimization of radiographic procedures in order to reduce the risks for neonates that, in spite of being considered to be low as compared with the benefits, should be reduced to values as low as reasonably achievable.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Dosimetria/efeitos adversos , Kerma , Neoplasias Induzidas por Radiação , Proteção Radiológica , Riscos de Radiação , Carcinógenos , Radiação Ionizante , Radiometria , Medição de Risco
13.
RFO UPF ; 13(2): 39-44, maio-ago. 2008.
Artigo em Português | LILACS, BBO | ID: lil-497081

RESUMO

Este estudo avaliou a radiopacidade dos cimentos endodônticos FillCanal®, Apexit®, Vidrion Endo® e Endométhasone®, variando o tempo de exposição (0,3 e 0,4s) e quilovoltagem (50 e 70 kVp). Para cada material estudado foram confeccionados cinco corpos-de-prova, os quais foram radiografados, juntamente com um dente, nos tempos de exposição e quilovoltagens determinados. Em cada imagem do corpo-de-prova e do dente foram realizadas cinco medidas da densidade óptica. Foram utilizados os testes de Kruskal-Wallis, para avaliar a influência dos fatores quilovoltagem, tempo de exposição e cimento, e de Mann-Whitney, para comparações múltiplas (p,0,05). Nas condições avaliadas, todos os materiais foram mais radiopacos que o dente. Com exceção do Endométhasone®®, que apresentou radiopacidade inferior em relação aos demais materiais nos dois tempos de exposição estudados, não houve diferença significativa entre os outros cimentos endodônticos avaliados quando a quilovoltagem empregada foi de 50 kVp. Quando os materiais foram expostos utilizando-se a quilovoltagem de 70 kVp, houve maior densidade óptica para o tempo 0,4 s e, nos dois tempos de exposição empregados, os valores de densidade apresentados pelos cimentos Vidrion Endo® e FillCanal® e Endométhasone® e Apexit® foram semelhantes. Concluiu-se que o fator quilovoltagem apresentou maior influência na radiopacidade dos materiais do que o tempo de exposição. Da mesma forma, pode-se dizer que a quilovoltagem de 70 kVp permite que a radiopacidade do material se diferencie pela densidade e composição deste.


Assuntos
Cimentos Dentários , Fenômenos Físicos , Radiografia Dentária , Obturação do Canal Radicular
14.
Radiol. bras ; 40(6): 409-413, nov.-dez. 2007. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-472001

RESUMO

OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.


OBJECTIVE: The present study was aimed at evaluating the frequency of radiographic assessment of paranasal sinuses in pediatric patients in hospitals of Belo Horizonte, MG, Brazil. Additionally, aspects regarding radiation protection conditions and radiographic parameters were evaluated, and entrance air kerma and organ doses were estimated. MATERIALS AND METHODS: Patients' data and parameters of radiographic technique employed in the assessment of children in the age range between 1 and 16 years were collected in five examination rooms of four hospitals in Belo Horizonte, also taking into consideration the radiation protection aspects. Entrance air kerma calculation was based on the x-ray tubes output, and organ doses were estimated with the PCXMC software. RESULTS: Mean entrance air kerma values found in the five rooms were, respectively, 1398 µGy, 829 µGy, 877 µGy, 1168 µGy and 3886 µGy for patients with ages between 1 and 5 years. CONCLUSION: Most frequently, mento-naso and fronto-naso views are requested in conjunction in the majority of hospitals, which increases the radiation dose to the patients. It may be concluded that the risks for patients can be reduced by means of the utilization of an appropriate x-ray field, non-utilization of antiscattering grids, selection of high voltages and lower exposure times.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Exposição à Radiação , Radiação Ionizante , Relação Dose-Resposta à Radiação , Sinusite , Doses de Radiação , Kerma
15.
Rev. bras. eng. biomed ; 23(3): 221-229, dez. 2007. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-507728

RESUMO

A mamografia é atualmente o método de diagnóstico mais eficaz para detecção de patologias nas mamas. Contudo, o uso de radiação ionizante está associado a um risco de indução de câncer nos pacientes, o que torna imprescindível a implantação de programas de conotrole de qualidade para a otimização do procedimento e a obtenção de imagens de qualidade para o diagnóstico com a menor dose ao paciente. Este trabalho tem como objetivo a avaliação da resposta de um distema dosimétrico desenvolvido para auxiliar nos programas de controle de qualidade em mamografia, através de medidas simultâneas da tensão do tudo de raios-X, do tempo de irradiação e do kerma ar na entrada da pele do paciente. Este sistema dosimétrico consiste de três sensores semicondutores (fotodiodos comerciais), acoplados a um sistema eletrônico e associados a um conjunto de filtros de Al e Cu. Um dos fotodiodos é usado para o controle do processo de leitura e medição do tempo de irradiação. A razão entre as leituras dos outros dois é utilizada para a determinação da tensão dotubo de raios-X através do método não invasivo baseado na diferença de atenuação com diferentes absorvedores. O sinal do semicondutor sem filtro também é usado para obter o valor do kerma no ar na entrada da pele do paciente. Todo processo de medição é controlado por um dispositivo microcontrolador e os valores obtidos são visualizados em um display. O instrumento foi testado em um equipamento de raios-X mamográfico. Os resultados obtidos mostraram uma resposta linear e uma repetibilidade de 2 por cento para as medidas do kerma ar na entrada da pele do paciente. A estabilidade na resposta da medida de tensão se mostrou reprodutível dentro de mais ou menos 1,5 por cento. O teste das medids do tempo de irradiação indicou uma variação inferior a 0,5 por cento.


Assuntos
Controle de Qualidade , Mamografia/métodos , Radiação Ionizante , Diagnóstico por Imagem/efeitos adversos , Diagnóstico por Imagem/normas , Diagnóstico por Imagem/tendências , Padrões de Referência
16.
Braz. j. oral sci ; 6(20): 1278-1282, Jan-Mar. 2007. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-850525

RESUMO

The aim of this study was to evaluate the radiopacity of four commercially available low-viscosity composites. The lowviscosity composites used in this study were Natural Flow, Flow It, Filtek Flow and Protect Liner F. Five specimens of each material were made in stainless-steel ring moulds of 10 mm diameter and 2 mm height. One specimen of each material and a 10-step aluminium wedge were radiographed in an occlusal film. The reading of the optical density was performed in five different locations in each radiographed specimen. The net optical density was calculated, and then the mean values were obtained, and related with the equivalent thickness of aluminium. The radiopacities of each composite, in millimeters of aluminium were: Flow It (3.24 ± 0.17); Filtek Flow (2.25 ± 0.17); Natural Flow (1.50 ± 0.13); Protect Liner F (<1 mm/Al). Flow It and Filtek Flow presented an acceptable radiopacity according to the ISO Standard 4049. Natural Flow and Protect Liner F did not supply the requirements for radiopacity, thus, these materials could be confounded with secondary caries in some clinical applications, such as restorations or cavity lining.


Assuntos
Resinas Compostas , Absorciometria de Fóton , Radiografia Dentária , Diagnóstico por Imagem , Viscosidade
17.
Radiol. bras ; 40(2): 119-122, mar.-abr. 2007. tab, graf
Artigo em Português | LILACS | ID: lil-455947

RESUMO

OBJETIVO: Foi realizada avaliação da dose de entrada na pele, da dose efetiva e da qualidade da imagem em radiografias de tórax de pacientes adultos. MATERIAIS E MÉTODOS: O estudo realizou-se em oito hospitais, sendo sete públicos (dois filantrópicos) e um particular nos municípios de Angra dos Reis, Cabo Frio, Campos dos Goytacazes, Itaperuna, Niterói, Recife e Rio de Janeiro. Foram avaliadas a dose de entrada na pele e a dose efetiva de 735 radiografias de tórax nas incidências póstero-anterior/ântero-posterior e perfil. No que se refere aos critérios de imagem, foram avaliadas 44 radiografias. RESULTADOS: Constatou-se variação de até nove vezes nos valores da dose de entrada na pele e de até seis vezes na dose efetiva para um mesmo tipo de projeção. Os valores das técnicas radiográficas também apresentaram grandes discrepâncias. A qualidade das imagens também não é boa, pois foi obtido valor médio de presença dos critérios de apenas 55 por cento. CONCLUSÃO: Há necessidade de melhoria/padronização de procedimentos em radiologia convencional, o que pode ser atingido se for implantado um programa de controle e garantia de qualidade no setor de radiologia, incluindo o treinamento dos técnicos, a aferição do desempenho dos equipamentos emissores de radiação e o controle sensitométrico do sistema de processamento radiográfico.


OBJECTIVE: Entrance skin dose, effective dose, and imaging quality in chest radiographs of adult patients have been evaluated. MATERIALS AND METHODS: The study has been developed in eight institutions - seven public hospitals (two of them philanthropic institutions) and one private - in the cities of Agra dos Reis, Cabo Frio, Campos dos Goytacazes, Itaperuna, Niterói, Recife and Rio de Janeiro. Entrance skin dose and effective dose have been evaluated in 735 chest radiographs obtained in posteroanterior/anteroposterior and lateral projections. As regards imaging criteria, 44 radiographs have been evaluated. RESULTS: Variations of up to nine times in entrance skin dose, and six times in effective dose have been detected for a same type of projection. Also, significant discrepancies have been found in values resulting from radiographic techniques employed. Besides, imaging quality has not been good since the rate of compliance with imaging criteria was only 55 percent. CONCLUSION: There is a pressing need for improvement/standardization of procedures in conventional radiology; this can be achieved by implementing a quality control and assurance program in the department of radiology, including training of technicians, x-ray equipment calibration, and sensitometric control of films processors.


Assuntos
Humanos , Dosimetria , Interpretação de Imagem Assistida por Computador , Radiografia Torácica , Controle de Qualidade , Radiografia Torácica/efeitos da radiação , Radiografia Torácica/tendências , Sensibilidade e Especificidade
18.
Rev. med. nucl. Alasbimn j ; 9(36)Apr. 2007. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-474903

RESUMO

Esta investigación propone un protocolo de planificación individualizada de dosis ablativas basado en el metabolismo individual del paciente y en la medida de la masa de los remanescientes tiroideanos. Utilizando SPECT, el metabolismo de I-131 fue estudiado en 9 pacientes tiroidectomizados, y la actividad optima para la terapia fue calculada y comparada con la actividad fija establecida de 3.7 GBq (100 mCi), que és en general administrada. Fue observado que 78 por ciento de las pacientes podrian tener recibido actividades reduzidas de 131I (de 0.8-3.2 GBq (20-87 mCi)). Además, 33 por ciento destes pacientes podrian recibir actividades tan bajas que no necesitarian internamiento hospitalar. Visando facilitar los calculos de la actividad terapeutica optima de 131I hacia pacientes individuales, un programa de planificación de dosis simples y rápido fue criado (PlanDose). Este protocolo de cálculo de actividades de 131I específicas para el paciente permite una mejor determinación de la dosis ablativa necesaria en caso de pacientes con carcinoma diferenciado de la tiroide, y és un ejemplo de optimización de la práctica de protección radiologica.


This investigation proposes a protocol for planning of thyroid ablation therapy for individual patients, based on individual patient metabolic data and measured thyroid remnant masses. Using SPECT, I-131 uptake and clearance was studied in 9 patients who had undergone thyroidectomies, and the optimum activity for their therapy was calculated and compared to the established fixed activity of 3.7 GBq (100 mCi), which normally would have been assigned. It was observed that 7 of the patients could have received reduced activities of 131I (from 0.8-3.2 GBq (20-87 mCi)). In addition, 3 patients could have received low enough activities to have been discharged from the hospital. To facilitate the calculations of the optimum therapeutic activity of 131I for individual patients, a computer program was created (PlanDose). This protocol of calculated optimal patient-specific 131I activities allows a better determination of the necessary ablative dose for patients with differentiated carcinoma of the thyroid, and is an important example of optimization of the practice of radiation protection.


Assuntos
Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Humanos , Neoplasias da Glândula Tireoide/radioterapia , Radioisótopos do Iodo/metabolismo , Radioisótopos do Iodo/uso terapêutico , Relação Dose-Resposta à Radiação , Tomografia Computadorizada de Emissão de Fóton Único , Dosagem Radioterapêutica , Fatores de Tempo , Neoplasia Residual/radioterapia , Neoplasias da Glândula Tireoide , Neoplasias da Glândula Tireoide/cirurgia , Radioisótopos do Iodo/administração & dosagem , Terapia Combinada , Tireoidectomia
19.
Radiol. bras ; 39(6): 429-434, nov.-dez. 2006. graf, ilus, tab
Artigo em Português | LILACS | ID: lil-442340

RESUMO

OBJETIVO: O objetivo deste trabalho consiste em estudar a influência da resolução espacial da sonda gama Europrobe que é utilizada em cirurgia radioguiada. MATERIAIS E MÉTODOS: Na técnica de cirurgia radioguiada, após a injeção de um radiotraçador no tumor primário, é utilizada uma sonda detectora de radiação gama a fim de determinar a localização do linfonodo sentinela. Para simular a região dos pontos de injeção do radiotraçador e o linfonodo sentinela, duas fontes de Tc-99m, com 20,42 MBq e 0,70 MBq, foram posicionadas no interior de um recipiente preenchido com água. Em seguida, com a janela de entrada da sonda coberta com um colimador, realizou-se varredura sobre a superfície da água. Assim, foi possível registrar a taxa de contagens variando-se a distância lateral da sonda em relação às duas fontes, as quais foram separadas por uma distância variando entre 30 mm e 60 mm. RESULTADOS: Os resultados mostraram que o uso do colimador contribui para melhorar a resolução espacial da sonda, permitindo a identificação do linfonodo sentinela distante até 30 mm do ponto de injeção. CONCLUSÃO: Esse estudo permite concluir que a sonda Europrobe, quando utilizada com capa colimadora com orifício central de 3,5 mm de diâmetro, é capaz de identificar o linfonodo sentinela posicionado a até 30 mm de distância em relação à região do ponto de injeção do radiotraçador.


OBJECTIVE: The aim of the present study is to evaluate the performance of the Europrobe gamma probe spatial resolution in radioguided surgery. MATERIALS AND METHODS: In the radioguided surgery technique, after a radiotracer injection into the primary tumor, a gamma detector probe is utilized to determine the localization of the sentinel lymph node. In order to simulate the region of the radiotracer injection the sentinel lymph node, two Tc-99m sources, with 20.42 MBq and 0.70 MBq, were positioned in a water-filled tank. With a collimator cap attached to the probe, scans over the water surface were made. So, the count rate was measured by means of lateral displacement of the probe in relation to the both sources with distances ranging between 30 mm and 60 mm. RESULTS: Results showed that the use of the collimator contributes to improve the spatial resolution of the probe allowing the identification of a sentinel lymph node within a distance up to 30 mm from the radiotracer injection point. CONCLUSION: The utilization of a collimator cap with a 3.5 mm diameter central orifice on a Europrobe gamma probe, allows the identification of a sentinel lymph node within a distance up to 30 mm from the radiotracer injection point.


Assuntos
Cirurgia Assistida por Computador/métodos , Linfonodos , Monitorização Intraoperatória , Cirurgia Assistida por Computador , Diagnóstico por Imagem/instrumentação , Câmaras gama
20.
Radiol. bras ; 36(2): 105-109, mar.-abr. 2003. tab, graf
Artigo em Português | LILACS | ID: lil-337820

RESUMO

OBJETIVO: Este trabalho tem como objetivo discutir os efeitos dos principais parâmetros que interferem na qualidade da imagem e na dose de entrada na pele do paciente. MATERIAIS E MÉTODOS: Foram acompanhadas radiografias pediátricas de tórax em três instituições. Em cada uma delas foram feitos testes de desempenho dos equipamentos de raios-X utilizados. A avaliação da dose de entrada na pele foi feita com a utilização de dosímetros termoluminescentes. RESULTADOS: Apenas um dos equipamentos de raios-X testados mostrou-se em condições aceitáveis de funcionamento. Os valores médios de dose de entrada na pele para os exames investigados, em função da faixa etária, foram: (0,22 ± 0,88) mGy para menores de 1 ano, (0,28 ± 0,11) mGy entre 1,1 e 4 anos, (0,26 ± 0,13) mGy entre 4,1 e 6 anos, (0,23 ± 0,13) mGy entre 6,1 e 10 anos e (0,26 ± 0,25) mGy para maiores de 10 anos. CONCLUSÃO: Os valores médios de dose de entrada na pele são bastante elevados se comparados aos níveis de referência adotados pela Comissão da Comunidade Européia e aos demais resultados encontrados na literatura pesquisada. Recomenda-se a implantação de programas de garantia de qualidade para a redução da dose-paciente com a obtenção de imagens com qualidade para o diagnóstico


OBJECTIVE: The aim of this work is to discuss the effects of the main parameters that influence image quality and the entrance skin dose. MATERIALS AND METHODS: The pediatric chest radiographs of three different Institutions were evaluated. Tests on all x-ray equipment were performed. The skin entrance dose was assessed using thermoluminescent dosimeters. RESULTS: Only one of all x-ray equipments tested was in good operation condition. The average skin entrance dose was: (0.222 ± 0.088) mGy for children under 1 year, (0.28 ± 0.11) mGy for 1.1 to 4 years, (0.26 ± 0.13) mGy for 4.1 to 6 years, (0.23 ± 0.13) mGy for 6.1 to 10 years and (0.26 ± 0.25) mGy for older than 10 years. CONCLUSION: The results showed that the average skin entrance doses are higher than the European Community Commission reference levels and other values reported in the literature. We recommend the implantation of quality assurance programs to reduce skin entrance doses and for obtaining good quality images.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Pediatria , Pele/efeitos da radiação , Radiologia , Dosagem Radioterapêutica , Relação Dose-Resposta à Radiação , Medição de Radiação , Radiologia/métodos , Dosímetros de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA